#ifndef PROPIPING_H
#define PROPIPING_H
#include <ProParamval.h>
#include <ProObjects.h>
#include <ProSelection.h>
#include <ProAsmcomp.h>
#include <ProAsmcomppath.h>
#include <ProSelection.h>
PRO_BEGIN_C_DECLS
/*##############################################################################
Functions/Data Definition for Linestock
##############################################################################*/
typedef enum
{
PROLNSTKPRM_SINGLE,
PROLNSTKPRM_MULTIPLE
} ProLnstkParamType;
typedef struct pro_lnstk
{
ProName name;
ProAssembly owner;
} ProLnstk;
typedef struct _pro_lnstk_param_memb_
{
ProName name;
ProParamvalue value;
} ProLnstkParamMemb;
typedef struct _pro_lnstk_param_
{
ProName name;
ProLnstkParamType param_type;
union {
ProParamvalue value;
ProLnstkParamMemb *members;
} lnstk_param_value;
} ProLnstkParam;
/*--------------------------------------------------------------------*\
Values of enumerable line stock parameters
\*--------------------------------------------------------------------*/
/* Values of Section Type parameter */
typedef enum
{
PROLNSTKPIPESECT_HOLLOW, /* Hollow */
PROLNSTKPIPESECT_SOLID /* Solid */
} ProLnstkPipeSection;
/* Values of X Section parameter */
typedef enum
{
PROLNSTKPIPEXSECT_CIRCULAR, /* Circular */
PROLNSTKPIPEXSECT_RECTANGULAR /* Rectangular */
} ProLnstkPipeXSection;
/* Values of Shape Type parameter */
typedef enum
{
PROLNSTKPIPESHAPE_STRT, /* Straight */
PROLNSTKPIPESHAPE_FLXBL /* Flexible */
} ProLnstkPipeShape;
/* Values of Corner Type parameter */
typedef enum
{
PROLNSTKPIPECRNR_FIT, /* Fitting */
PROLNSTKPIPECRNR_MCUT, /* Miter Cut */
PROLNSTKPIPECRNR_BEND /* Bend */
} ProLnstkPipeCrnrType;
/*-----------------------------------------------------------------------*\
Functions to manage linestocks.
\*-----------------------------------------------------------------------*/
extern ProError ProAssemblyLnstksCollect( ProAssembly assy,
ProLnstk **pro_lnstks);
/*
Purpose: Collect linestocks in specified assembly
Input Arguments:
assy - Assembly owner of the linestock
Output Arguments:
pro_lnstks - ProArray of linestock's handles. Function allocates memory
for this argument. Use ProArrayFree to free it.
Return Values:
PRO_TK_NO_ERROR - The function successfully initialize linestock.
PRO_TK_BAD_INPUTS - The some arguments is invalid.
PRO_TK_E_NOT_FOUND - No linestock found.
PRO_TK_GENERAL_ERROR - Other error.
*/
extern ProError ProPipelineLnstkGet( ProFeature *pipeline,
ProLnstk *pro_lnstk);
/*
Purpose: Get linestock assigned to pipeline feature.
Input Arguments:
pipeline - The pipeline feature.
Output Arguments:
pro_lnstk - The linestock handle.
Return Values:
PRO_TK_NO_ERROR - The linestock assigned to pipeline found.
PRO_TK_BAD_INPUTS - One or more of the arguments are invalid.
PRO_TK_GENERAL_ERROR - Other error.
*/
extern ProError ProPipelineLnstkSet( ProFeature *pipeline,
ProLnstk *pro_lnstk);
/*
Purpose: Assign linestock to pipeline feature.
Input Arguments:
pipeline - The pipeline feature.
pro_lnstk - The linestock handle.
Output Arguments:
none
Return Values:
PRO_TK_NO_ERROR - The linestock successfully assigned to pipeline.
PRO_TK_NO_CHANGE - The linestock is already set to pipeline.
PRO_TK_BAD_INPUTS - One or more of the arguments are invalid.
PRO_TK_E_NOT_FOUND - New line stock does not exist.
PRO_TK_GENERAL_ERROR - Other error.
*/
extern ProError ProLnstkParametersCollect( ProLnstk *lnstk,
ProLnstkParam **p_params);
/*
Purpose: Retrieves parameters of specified linestock
Input Arguments:
lnstk - Handle of linestock.
Output Arguments:
p_params - ProArray of parameters. The function allocates memory for
these arguments. To free it, call the function ProArrayFree.
Return Values:
PRO_TK_NO_ERROR - The function successfully retrieved parameters.
PRO_TK_BAD_INPUTS - One or more of the arguments are invalid.
PRO_TK_E_NOT_FOUND - Lnestock with this name does not exist.
PRO_TK_GENERAL_ERROR - Other error.
*/
extern ProError ProLnstkParametersSet( ProLnstk *lnstk,
ProLnstkParam *p_params);
/*
Purpose: Set parameters for specified linestock
Input Arguments:
lnstk - Handle of linestock.
p_params - ProArray of new parameters.
Output Arguments:
none
Return Values:
PRO_TK_NO_ERROR - The function successfully sets new parameters.
PRO_TK_BAD_INPUTS - One or more of the arguments are invalid.
PRO_TK_E_NOT_FOUND - Linestock with this name does not exist.
PRO_TK_GENERAL_ERROR - Other error.
*/
extern ProError ProLnstkCreate( ProAssembly assy,
ProName w_name );
/*
Purpose: Creates new linestock
Input Arguments:
assy - The handle of linestocks assembly owner.
w_name - The linestock name.
Output Arguments:
none
Return Values:
PRO_TK_NO_ERROR - The function successfully creates new linestock.
PRO_TK_BAD_INPUTS - One or more of the arguments are invalid.
PRO_TK_E_FOUND - Linestock with this name already exist.
PRO_TK_GENERAL_ERROR - Other error.
*/
extern ProError ProLnstkParameterAdd( ProLnstk *lnstk,
ProLnstkParam *p_param );
/*
Purpose: Add parameter in specified linestock
Input Arguments:
lnstk - Handle of linestock.
p_param - Parameter handle.
Output Arguments:
none
Return Values:
PRO_TK_NO_ERROR - The function successfully add parameter.
PRO_TK_BAD_INPUTS - One or more of the arguments are invalid.
PRO_TK_E_NOT_FOUND - Linestock with this name does not exist.
PRO_TK_GENERAL_ERROR - Other error.
*/
extern ProError ProLnstkParameterDelete( ProLnstk *lnstk,
ProName w_param_name);
/*
Purpose: Deletes parameter in specified linestock
Input Arguments:
lnstk - Handle of linestock.
w_param_name - Name of retrieved parameter
Output Arguments:
none
Return Values:
PRO_TK_NO_ERROR - The function successfully delete parameter.
PRO_TK_BAD_INPUTS - One or more of the arguments are invalid.
PRO_TK_E_NOT_FOUND - Linestock with this name does not exist.
PRO_TK_GENERAL_ERROR - Other error.
*/
/*##############################################################################
Functions/Data Definition for Pipeline feature
##############################################################################*/
typedef enum
{
PROPIPINGSPEC_RIGID,
PROPIPINGSPEC_HOSE /* not supported in creo2.0 */
} ProPipingSpecType;
typedef struct pro_piping_rigid_spec_params__
{
ProName schedule; /* SCHEDULE from specdb. */
} ProPipingRigidSpecParams;
typedef struct pro_piping_hose_spec_params_
{
ProName pressure;
} ProPipingHoseSpecParams;
typedef struct _PipeSpecParams_
{
ProName spec; /* pipe specification */
ProName size; /* pipe size from specdb */
ProName grade; /* material code (grade) */
ProName category; /* pipe category (PIPE/FLEX_PIPE) */
ProPipingSpecType catalog_type; /* PROPIPINGSPEC_RIGID/HOSE */
union {
ProPipingRigidSpecParams rigid_params;
ProPipingHoseSpecParams hose_params;
} t;
} ProPipingSpecParams;
extern ProError ProPipelineSpecDrivenCreate( ProSelection model,
ProPipingSpecParams spec_params,
ProName Mnemonic,
ProName number,
ProName insulation,
ProBool CreateSubAsm,
ProName SubAsmName,
ProSelection csys_reference,
ProLnstk *pro_lnstk,
ProFeature *pro_pipeline,
ProSelection *pro_new_model );
/*
Purpose: Creates a linestock feature according to the spec parameters, and
a pipeline feature with those spec params, referencing the
linestock. The pipeline features name would be generated according
to the spec params and config option "pipeline_label_format". The
linestock features name would be generated according to the spec
params.
Input Arguments:
model - The model where the pipeline will be create in. Must be a spec
driven model or under confic option piping_design_method spec
driven.
spec_params - The parameters according to which the pipeline and
linestock features will be created.
Mnemonic - May be NULL or empty. If NULL then the default mnemonic will
be used, according to the spec params. (use an empty string
to specify that no mnemonic shall be used).
number - May be NULL or empty.
insulation - May be NULL or empty. If NULL then the default insulation
will be used, according to the spec params. (use an empty
string to specify that no insulation shall be used).
CreateSubAsm - If PRO_B_TRUE then the sub assembly will be created for
that pipeline (using a template model defined in config
option pipeline_start_assembly_name).
SubAsmName - The name of the sub assembly. Used if CreateSubAsm is
TRUE. May be NULL. If NULL or empty, then the name of the
sub assembly will be generated according to the config
option pipeline_assembly_name_format.
csys_reference - A csys in the given model, to which the sub assembly
will reference. May be NULL. If NULL then the first
csys of the model will be used for placement
reference.
Output Arguments:
pro_lnstk - The linestock created during this process.
pro_pipeline - The pipeline created during this process.
pro_new_model - The sub assembly created during this process (if
CreateSubAsm is TRUE).
Return Values:
PRO_TK_NO_ERROR - The function successfully creates the pipeline, the
linestock, and the sub assembly (when relevant).
PRO_TK_BAD_INPUTS - One or more of the arguments are invalid.
PRO_TK_E_FOUND - Pipeline with those exact params already exists or Sub
assembly with the given name or the generated names
exists. PRO_TK_E_NOT_FOUND One of the spec parameters
was not found. Some examples: SPEC not found in
pipe_spec_directory_file. SIZE not found in the
related auto select file. A specific message will be
prompt to Creo window.
PRO_TK_GENERAL_ERROR - Other error.
*/
extern ProError ProPipelineCreateFromXML( ProSelection model,
ProPath xml_file,
ProName pipeline_label,
ProBool insulation,
ProBool CreateSubAsm,
ProName SubAsmName,
ProSelection csys_reference,
ProLnstk *pro_lnstk,
ProFeature *pro_pipeline,
ProSelection *pro_new_model );
/*
Purpose: Given XML file and a pipeline label, creates linestock feature and
pipeline feature, according to the spec params taken from the XML
for the specific label. The pipeline features name would be
generated according to the spec params and config option
"pipeline_label_format". The linestock features name would be
generated according to the spec params.
Input Arguments:
model - The model where the pipeline will be create in. Must be a spec
driven model or under confic option piping_design_method spec
driven.
xml_file - A path to XML file for schematic driven pipelines.
pipeline_label - A label of a pipeline for the above XML file. The spec
parameters will be filled from the XML file for that
label: SPEC, SIZE, SCHEDULE, MNEMONIC, NUMBER and
INSULATION. Category is PIPE. GRADE (Material code)
will be taken from the related spec according to the
other spec params.
insulation - if TRUE then insualtion will be created for the pipeline
according to parameter INSULATION taken form the XML file.
CreateSubAsm - If PRO_B_TRUE then the sub assembly will be created for
that pipeline (using a template model defined in config
option pipeline_start_assembly_name).
SubAsmName - The name of the sub assembly. Used if CreateSubAsm is
TRUE. May be NULL. If NULL or empty, then the name of the
sub assembly will be generated according to the config
option pipeline_assembly_name_format.
csys_reference - A csys in the given model, to which the sub assembly
will reference. May be NULL. If NULL then the first
csys of the model will be used for placement
reference.
Output Arguments:
pro_lnstk - The linestock created during this process.
pro_pipeline - The pipeline created during this process.
pro_new_model - The sub assembly created during this process (if
CreateSubAsm is TRUE).
Return Values:
PRO_TK_NO_ERROR - The function successfully creates the pipeline, the
linestock, and the sub assembly (when relevant).
PRO_TK_BAD_INPUTS - One or more of the arguments are invalid.
PRO_TK_INVALID_FILE - XML file was not found or invalid.
PRO_TK_E_NOT_FOUND The given label was not found
in the XML file OR one of the spec parameters was
not found. Some examples: spec is not found in
pipe_spec_directory_file. size is not found in
the related auto select file. A specific message
will be prompt to Creo window.
PRO_TK_E_FOUND - Pipeline with those exact params already exists or Sub
assembly with the given name or the generated names
exists.
PRO_TK_GENERAL_ERROR - Other error.
*/
extern ProError ProPipelineCreate ( ProSelection model,
ProLnstk *lnstk,
ProName pipeline_name,
ProFeature *pro_pipeline);
/*
Purpose: Creates a non spec driven pipeline feature. The feature will be
created under the given model, with the given name pipeline_name,
referencing pro_lnstk.
Input Arguments:
model - the model where the pipeline will be create in. must be a non
spec driven model.
lnstk - the linestocl to which the pipeline will reference. must belong
to the input model.
pipeline_name - the name of the pipeline.
Output Arguments:
pro_pipeline - the newly created pipeline feature.
Return Values:
PRO_TK_NO_ERROR - The function successfully creates the pipeline.
PRO_TK_BAD_INPUTS One or more of the arguments are
invalid (Model is invalid OR the linestocks owner is
different than model). PRO_TK_E_NOT_FOUND Linestock
was not found for the specific ProLnstk data (owner
and name).
PRO_TK_INVALID_NAME - Pipeline with this name already exist.
PRO_TK_GENERAL_ERROR - Other error.
*/
extern ProError ProPipelineParametersCollect( ProFeature *pipeline,
ProLnstkParam **p_params );
/*
Purpose: Retrieves parameters of specified pipeline.
Input Arguments:
pipeline - Handle of pipeline feature.
Output Arguments:
p_params - ProArray of parameters. The function allocates memory for
these arguments. To free it, call the function ProArrayFree.
Return Values:
PRO_TK_NO_ERROR - The function successfully retrieved parameters.
PRO_TK_BAD_INPUTS - One or more of the arguments are invalid.
PRO_TK_GENERAL_ERROR - Other error.
*/
extern ProError ProPipelineParameterAdd( ProFeature *pipeline,
ProLnstkParam *p_param );
/*
Purpose: Add parameter in specified pipeline.
Input Arguments:
pipeline - Handle of pipeline feature.
p_param - Parameter handle.
Output Arguments:
none
Return Values:
PRO_TK_NO_ERROR - The function successfully add parameter.
PRO_TK_BAD_INPUTS - One or more of the arguments are invalid.
PRO_TK_GENERAL_ERROR - Other error.
*/
extern ProError ProPipelineParameterDelete( ProFeature *pipeline,
ProName param_name );
/*
Purpose: Deletes parameter in specified pipeline.
Input Arguments:
pipeline - Handle of pipeline feature.
param_name - Name of retrieved parameter
Output Arguments:
none
Return Values:
PRO_TK_NO_ERROR - The function successfully delete parameter.
PRO_TK_BAD_INPUTS - One or more of the arguments are invalid.
PRO_TK_GENERAL_ERROR - Other error.
*/
extern ProError ProPipelineParametersSet( ProFeature *pipeline,
ProLnstkParam *p_params );
/*
Purpose: Set parameters for specified pipeline.
Input Arguments:
pipeline - Handle of pipeline feature.
p_params - ProArray of new parameters.
Output Arguments:
none
Return Values:
PRO_TK_NO_ERROR - The function successfully sets new parameters.
PRO_TK_BAD_INPUTS - One or more of the arguments are invalid.
PRO_TK_GENERAL_ERROR - Other error.
*/
/*##############################################################################
Functions/Data Definition for Pipe Network Building/Visiting/Data Retrieving
##############################################################################*/
/* Pipe Network terminology and structure
-----------------------------------------
Hierarchy of items...
Network contains a list of
Extension contains a list of
Member can be
Terminator contains one
Feature
or
nothing
or
Series contains a list of
Object can be
Segment
or
Fitting
or
Juntion contains one
Object can be
Fitting
or
Stubin
Pipeline is set of interconnecting pipes and fitments.
A Pipeline feature is a feature which names the pipeline,
and to which all the other features in a pipeline
refer, as a way to show their grouping. It does not
contain any geometry of its own.
Network is a data structure which contains references
to the pipline objects, structured to show their
connectivity and sequence in relation to the flow. A pipeline
consists of a main extension, plus other extensions which
branch from it, then others which branch from those, and
so on recursively
Extension is a non-branching sequence of pipeline members,
which terminates at open ends (i.e. no further pipeline items
attached)non-open ends (i.e. equipment nozzles or other
pipelines) or junctions.
At a branch (or Junction), pipes are grouped into
extensions such that the extension which continues
across the branch has a continuous direction of
flow, and, if that criterion leaves a choice, has
the smallest change of direction
possible for that branch. Other pipes which join
that branch then form the end points of other
extensions.
Member (of an extension) is a terminator or a series or a junction.
Terminator is the open or non-open ends of the pipeline.
Series is a non-branching sequence of pipeline objects.
Junction is a fitting or a stubin which represents
a part which joins three or more pipe segments,
Object is a Segment or a Fitting or a Stubin or a Selection or a Group.
Segment is a section of pipe, either straight, or
arced in which case it is manufactured by taking
a straight section of tube and bending it.
Fitting is a component that connects with pipe segments,
e.g. to form a corner where space does not allow a
bent pipe segment, or to represent an item such as
a valve.
Stubin is a datum point which joints three or more series.
Selection is a feature that is normally at the termination of the pipeline.
Group is a set of fittings that are inserted as one component, such as vent. */
/*##############################################################################
Data Definition
##############################################################################*/
typedef struct PipeNetworkInfo *ProPnetwork;
typedef struct PExtension *ProPextension;
typedef struct PMember *ProPmember;
typedef struct PSeries *ProPseries;
typedef struct PJunction *ProPjunction;
typedef struct PObject *ProPobject;
typedef struct PSegment *ProPsegment;
typedef struct PFitting *ProPfitting;
typedef struct PStubin *ProPstubin;
typedef struct PTerminator *ProPterminator;
typedef struct PSelection *ProPselection;
typedef struct PGroup *ProPgroup;
typedef enum
{
PROPFLOWDIRECTION_UNKNOWN = 0,
PROPFLOWDIRECTION_NORMAL = 1, /* Member sequence is the same as flow dir */
PROPFLOWDIRECTION_REVERSE = 2 /* Member sequence is opposite to the flow */
} ProPflowDirection;
typedef enum
{
PROPMEMBERTYPE_UNKNOWN = 0,
PROPMEMBERTYPE_SERIES = 1,
PROPMEMBERTYPE_JUNCTION = 2,
PROPMEMBERTYPE_TERMINATOR = 3
}ProPmemberType;
typedef enum
{
PROPOBJECTTYPE_UNKNOWN = 0,
PROPOBJECTTYPE_SEGMENT = 1,
PROPOBJECTTYPE_FITTING = 2,
PROPOBJECTTYPE_STUBIN = 3,
PROPOBJECTTYPE_SELECTION = 4,
PROPOBJECTTYPE_GROUP = 5
} ProPobjectType;
typedef enum
{
PROPSEGMENTTYPE_UNKNOWN = 0,
PROPSEGMENTTYPE_STRAIGHT = 1, /* Straight pipe segment without bend */
PROPSEGMENTTYPE_BEND = 2 /* Pipe segment with bend(s) */
}ProPsegmentType;
typedef enum
{
PROPENTITYTYPE_UNKNOWN = 0,
PROPENTITYTYPE_STRAIGHT = 1, /* Straight pipe entity */
PROPENTITYTYPE_BEND = 2, /* Bend pipe entity */
PROPENTITYTYPE_MITER = 3 /* Miter pipe entity */
}ProPentityType;
typedef enum
{
PROPTERMINATORTYPE_UNKNOWN = 0,
PROPTERMINATORTYPE_IN = 1, /* Flow is in to this terminator */
PROPTERMINATORTYPE_OUT = 2 /* Flow is out from this terminator */
}ProPterminatorType;
/*##############################################################################
Function Definition
##############################################################################*/
extern ProError ProPipelineNetworkEval(
ProFeature *pipeline,
ProPnetwork *network);
/*
Purpose: Evaluates the network defined by the specified pipeline feature.
This is first step in evaluating the geometry and other properties
of a pipeline.
Input Arguments:
pipeline - The feature handle of the pipeline feature
Output Arguments:
network - The handle of the network structure. The handle is an opaque
pointer to a structure which is accessed by functions
starting with ProPnetwork. The data in the underlying data
structure is allocated by the function and should be freed
when no longer needed by calling ProPnetworkFree().
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
PRO_TK_BAD_CONTEXT - The feature was not a pipeline.
PRO_TK_NO_LICENSE - No Pro/PIPING license is available.
*/
/*============================================================================*/
extern ProError ProPnetworkFree(
ProPnetwork network);
/*
Purpose: Frees the structure underlying a pipeline network.
Input Arguments:
network - The network
Output Arguments:
none
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
/*============================================================================*/
extern ProError ProPnetworkLabelGet(
ProPnetwork network,
ProLine label);
/*
Purpose: Outputs the label for a pipeline network
Input Arguments:
network - The pipeline network
Output Arguments:
label - The label
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
/*============================================================================*/
extern ProError ProPnetworkSizeGet(
ProPnetwork network,
ProLine size);
/*
Purpose: Gets the size indicated in the label of the specified pipeline
network
Input Arguments:
network - The pipeline network.
Output Arguments:
size - The size string
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
/*============================================================================*/
extern ProError ProPnetworkSpecGet(
ProPnetwork network,
ProLine spec);
/*
Purpose: Gets the specification indicated in the label of the specified
pipeline network
Input Arguments:
network - The pipeline network.
Output Arguments:
spec - The specification string
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
/*============================================================================*/
typedef ProError (*ProPextensionVisitAction)(
ProPextension extension,
ProError status,
ProAppData data);
/*
Purpose: This is the generic visit action function for visiting a pipeline
extension
Input Arguments:
extension - The pipeline extension
status - The status from the filter function
data - The application data passed to the visit function
Output Arguments:
none
Return Values:
PRO_TK_NO_ERROR - Continue visiting items
Other - Do not visit any further items.
*/
/*============================================================================*/
typedef ProError (*ProPextensionFilterAction)(
ProPextension extension,
ProAppData data);
/*
Purpose: This is the generic filter action function for visiting a pipeline
extension
Input Arguments:
extension - The pipeline extension
data - The application data passed to the visit function
Output Arguments:
none
Return Values:
PRO_TK_CONTINUE - Skip the call to the action function for this item,
but continue with visiting later items.
Other - Call the action function for this item with this value as the
status input argument.
*/
/*============================================================================*/
extern ProError ProPnetworkExtensionVisit(
ProPnetwork network,
ProPextensionVisitAction visit_action,
ProPextensionFilterAction filter_action,
ProAppData data);
/*
Purpose: The visit function for visiting the extensions in a pipeline
network.
Input Arguments:
network - The network
visit_action - The visit action function
filter_action - The filter action function. If NULL, all extensions in
a pipeline network are visited using the action
function.
data - Application data being passed to filter and action functions.
Output Arguments:
none
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
PRO_TK_E_NOT_FOUND - No extensions
*/
/*============================================================================*/
extern ProError ProPextensionFlowGet(
ProPextension extension,
ProPflowDirection *flow);
/*
Purpose: Outputs the flow direction of the specified pipe extension
Input Arguments:
extension - The extension
Output Arguments:
flow - The flow direction
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
/*============================================================================*/
typedef ProError (*ProPmemberVisitAction)(
ProPmember member,
ProError status,
ProAppData data);
/*
Purpose: This is the generic visit action function for visiting a pipeline
extension member
Input Arguments:
member - The pipeline extension member
status - The status from the filter function
data - The application data passed to the visit function
Output Arguments:
none
Return Values:
PRO_TK_NO_ERROR - Continue visiting items
Other - Do not visit any further items.
*/
/*============================================================================*/
typedef ProError (*ProPmemberFilterAction)(
ProPmember member,
ProAppData data);
/*
Purpose: This is the generic filter action function for visiting a pipeline
extension member
Input Arguments:
member - The pipeline extension member
data - The application data passed to the visit function
Output Arguments:
none
Return Values:
PRO_TK_CONTINUE - Skip the call to the action function for this item,
but continue with visiting later items.
Other - Call the action function for this item with this value as the
status input argument.
*/
/*============================================================================*/
extern ProError ProPextensionMemberVisit(
ProPextension extension,
ProPmemberVisitAction visit_action,
ProPmemberFilterAction filter_action,
ProAppData data);
/*
Purpose: The visit function for visiting the members in a pipeline
extension.
Input Arguments:
extension - The extension
visit_action - The visit action function
filter_action - The filter action function. If NULL, all members in a
pipeline extension are visited using the action
function.
data - Application data to pass to the filter and action functions.
Output Arguments:
none
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
PRO_TK_E_NOT_FOUND - No members
*/
/*============================================================================*/
extern ProError ProPmemberTypeGet(
ProPmember member,
ProPmemberType *type);
/*
Purpose: Outputs the type of the specified pipeline extension member
Input Arguments:
member - The extension member
Output Arguments:
type - The type of the extension member
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
/*============================================================================*/
extern ProError ProPmemberSeriesGet(
ProPmember member,
ProPseries *series);
/*
Purpose: Outputs the series of the specified pipeline extension member
Input Arguments:
member - The extension member
Output Arguments:
series - The series
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
PRO_TK_BAD_CONTEXT - The member was not of type series.
*/
/*============================================================================*/
extern ProError ProPmemberJunctionGet(
ProPmember member,
ProPjunction *junction);
/*
Purpose: Outputs the junction of the specified pipeline extension member
Input Arguments:
member - The extension member
Output Arguments:
junction - The junction
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
PRO_TK_BAD_CONTEXT - The member was not of type junction.
*/
/*============================================================================*/
extern ProError ProPmemberTerminatorGet(
ProPmember member,
ProPterminator *terminator);
/*
Purpose: Outputs the terminator of the specified pipeline extension member
Input Arguments:
member - The extension member
Output Arguments:
terminator - The terminator
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
PRO_TK_BAD_CONTEXT - The member was not of type terminator.
*/
/*============================================================================*/
extern ProError ProPterminatorTypeGet(
ProPterminator terminator,
ProPterminatorType *type);
/*
Purpose: Outputs the type of the specified pipeline terminator
Input Arguments:
terminator - The terminator
Output Arguments:
type - The type of the terminator
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
/*============================================================================*/
typedef ProError (*ProPobjectVisitAction)(
ProPobject object,
ProError status,
ProAppData data);
/*
Purpose: This is the generic visit action function for visiting pipeline
objects
Input Arguments:
object - The pipeline object
status - The status from the filter function
data - The application data passed to the visit function
Output Arguments:
none
Return Values:
PRO_TK_NO_ERROR - Continue visiting items
Other - Do not visit any further items.
*/
/*============================================================================*/
typedef ProError (*ProPobjectFilterAction)(
ProPobject object,
ProAppData data);
/*
Purpose: This is the generic filter action function for visiting pipeline
objects
Input Arguments:
object - The pipeline object
data - The application data passed to the visit function
Output Arguments:
none
Return Values:
PRO_TK_CONTINUE - Skip the call to the action function for this item,
but continue with visiting later items.
Other - Call the action function for this item with this value as the
status input argument.
*/
/*============================================================================*/
extern ProError ProPseriesObjectVisit(
ProPseries series,
ProPobjectVisitAction visit_action,
ProPobjectFilterAction filter_action,
ProAppData data);
/*
Purpose: The visit function for visiting the objects in a pipeline series.
Input Arguments:
series - The series
visit_action - The visit action function
filter_action - The filter action function. If NULL, all objects in a
pipeline series are visited using the action function.
data - Application data to be passed to the filter and action
functions.
Output Arguments:
none
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
PRO_TK_E_NOT_FOUND - No objects
*/
/*============================================================================*/
extern ProError ProPjunctionObjectGet(
ProPjunction junction,
ProPobject *object);
/*
Purpose: Outputs the object contained by a pipeline junction.
Input Arguments:
junction - The junction
Output Arguments:
object - The object contained by the junction
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
/*============================================================================*/
extern ProError ProPterminatorObjectGet(
ProPterminator terminator,
ProPobject *object);
/*
Purpose: Outputs the object contained by a pipeline terminator.
Input Arguments:
terminator - The terminator
Output Arguments:
object - The object contained by the terminator
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
/*============================================================================*/
extern ProError ProPobjectTypeGet(
ProPobject object,
ProPobjectType *type);
/*
Purpose: Outputs the type of the specified pipeline object.
Input Arguments:
object - The pipeline object.
Output Arguments:
type - The object type.
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
/*============================================================================*/
extern ProError ProPobjectSegmentGet(
ProPobject object,
ProPsegment *segment);
/*
Purpose: Outputs the segment object for a pipeline object whose type is
segment.
Input Arguments:
object - The pipeline object.
Output Arguments:
segment - The segment
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS PRO_TK_BAD_CONTEXT
*/
/*============================================================================*/
extern ProError ProPobjectFittingGet(
ProPobject object,
ProPfitting *fitting);
/*
Purpose: Outputs the fitting object for a pipeline object whose type is
fitting.
Input Arguments:
object - The pipeline object.
Output Arguments:
fitting - The fitting
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS PRO_TK_BAD_CONTEXT
*/
/*============================================================================*/
extern ProError ProPobjectStubinGet(
ProPobject object,
ProPstubin *stubin);
/*
Purpose: Outputs the stubin object for a pipeline object whose type is
stubin.
Input Arguments:
object - The pipeline object.
Output Arguments:
stubin - The stubin
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS PRO_TK_BAD_CONTEXT
*/
/*============================================================================*/
extern ProError ProPobjectSelectionGet(
ProPobject object,
ProPselection *selection);
/*
Purpose: Outputs the selection object for a pipeline object whose type is
selection.
Input Arguments:
object - The pipeline object.
Output Arguments:
selection - The selection
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS PRO_TK_BAD_CONTEXT
*/
/*============================================================================*/
extern ProError ProPsegmentTypeGet(
ProPsegment segment,
ProPsegmentType *type);
/*
Purpose: Outputs the type of a pipeline segment
Input Arguments:
segment - The segment
Output Arguments:
type - The segment type (straight or bend)
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
/*============================================================================*/
extern ProError ProPsegmentLinestockGet(
ProPsegment segment,
ProLnstk *linestock);
/*
Purpose: Outputs the linestock for a specified pipeline segment
Input Arguments:
segment - The segment
Output Arguments:
linestock - The linestock
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS PRO_TK_BAD_CONTEXT
*/
/*============================================================================*/
extern ProError ProPsegmentLengthGet(
ProPsegment segment,
double *length);
/*
Purpose: Outputs the length of a specified pipeline segment
Input Arguments:
segment - The segment
Output Arguments:
length - The length
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
/*============================================================================*/
extern ProError ProPsegmentCurvesGet(
ProPsegment segment,
ProCurve **curves);
/*
Purpose: Outputs an array of curves which describe the geometry of a
specified pipeline segment
Input Arguments:
segment - The segment
Output Arguments:
curves - A ProArray of the curves. Access the curve geometry using
ProCurveDataGet(). The array is allocated by the function, and
should be freed after use by calling ProArrayFree(). The
curves are opaque pointers to data inside Creo Parametric.
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
PRO_TK_E_NOT_FOUND - No curves
*/
/*============================================================================*/
extern ProError ProPstubinPointGet(
ProPstubin stubin,
ProPoint *point);
/*
Purpose: Outputs the point entity which holds the stubin branch
Input Arguments:
stubin - The stubin
Output Arguments:
point - A ProPoint of the stubin.
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
PRO_TK_E_NOT_FOUND - No point
*/
/*============================================================================*/
extern ProError ProPfittingAsmcompGet(
ProPfitting fitting,
ProAsmcomp *asmcomp);
/*
Purpose: Outputs the assembly component that forms the specified pipeline
fitting.
Input Arguments:
fitting - The fitting
Output Arguments:
asmcomp - The assembly component
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
/*============================================================================*/
extern ProError ProPselectionSelectionGet(
ProPselection selection,
ProSelection *pro_selection);
/*
Purpose: Outputs the ProSelection of the specified ProPselection.
Input Arguments:
selection - The ProPselection
Output Arguments:
pro_selection - The ProSelection. Its memory are allocated by the
function and should be freed using ProSelectionFree().
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
/*============================================================================*/
extern ProError ProPjunctionSeriesIdsGet(
ProPjunction junction,
int **in_series_ids,
int **out_series_ids);
/*
Purpose: Outputs ids of the series connect to at the specified junction
Input Arguments:
junction - The junction
Output Arguments:
in_series_ids - A ProArray of ids of the series that flow in to this
junction. If NULL is given, no in series ids will be
returned. The ProArray is allocated by the function and
should be freed using ProArrayFree().
out_series_ids - A ProArray of ids of the series that flow out from
this junction. If NULL is given, no out series ids
will be returned. The ProArray is allocated by the
function and should be freed using ProArrayFree().
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
/*============================================================================*/
extern ProError ProPseriesIdGet(
ProPseries series,
int *series_id );
/*
Purpose: Outputs the series id of the specified series. Series id is a
sequential number that is used to identify a series.
Input Arguments:
series - The series
Output Arguments:
series_id - The series id
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
/*============================================================================*/
extern ProError ProSelectionPipelineGet(
ProSelection selection,
ProFeature *pipeline);
/*
Purpose: Outputs the pipeline feature representing the pipeline to which
the specified pipeline selection belongs.
Input Arguments:
selection - The selection. It must be a piping routing feature or the
pipeline feature itself.
Output Arguments:
pipeline - The pipeline feature
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
/*============================================================================*/
extern ProError ProPobjectPipelineGet(
ProSelection selection,
ProFeature *pipeline);
/*
Purpose: Outputs the pipeline feature representing the pipeline to which
the specified pipeline selection belongs. NOTE: This function has
been replaced by ProSelectionPipelineGet(). Please do NOT use it,
use ProSelectionPipelineGet() instead.
Input Arguments:
selection - The selection
Output Arguments:
pipeline - The pipeline feature
Return Values:
PRO_TK_NO_ERROR PRO_TK_BAD_INPUTS
*/
PRO_END_C_DECLS